PosiTector® App
Help Guide for
PosiTest AT-A Adhesion Testers


Introduction

The PosiTest AT-A measures adhesion of coatings to metal, wood, concrete and other rigid substrates. This help guide specifically covers using the PosiTector App to create customized, professional PDF reports, add images, notes, nature of fracture and more.


 

Getting Started

The PosiTector App uses Bluetooth (BLE) wireless technology to communicate with the PosiTest AT-A. Your device must support Bluetooth Smart (also know as Bluetooth Low Energy, BLE or Bluetooth 4.0).

Screen fonts, brightness and displayed language are inherited from your smart device settings. Currently, the PosiTector App has language support for English, Spanish, French, German, Chinese and Korean. Screen orientation is fixed to portrait only, rotation to landscape is not supported.

Connecting to a PosiTest AT-A

1. Ensure the PosiTest AT-A is powered-on and Bluetooth is active (Bluetooth icon will be displayed).

2. Select the PosiTector App icon on your smart device.

3. A list of available instruments (listed by model and serial number) will be displayed. Select to connect. The Bluetooth icon on the PosiTest AT-A will illuminate solid blue when successfully connected.


Once connected, stored batch readings and associated data are automatically copied from the PosiTest AT-A to the PosiTector App (on your smart device). The first time you connect to the PosiTest AT-A, you will have to open a batch by selecting Menu > Memory > Open (as shown below).

The next time the PosiTector App is opened, the last opened batch will be displayed. To open a different batch, follow the above instructions.

If no batches are present within the Open Batch menu, ensure Bluetooth is active and select Send Batch from the PosiTest AT-A's Connect menu. This option will manually transfer the measurement data the PosITector App. This is typically only necessary when connecting to another smart device for the first time.


If the PosiTector App is uninstalled or a menu Reset is performed, all stored measurements and associated data are permanently erased.

Prior to uninstalling the PosiTector App or performing a Reset it is recommended that you synchronize/copy measurement data to PosiSoft.net or share the batch data (AirPrint or email report). This ensures that the data is saved for future reference.

User Interface
The user interface was designed to combine the proven simplicity of our instruments and the advanced functionality of a smart device's features including touch, swipe, keyboard, camera and more. The interface will be instantly recognizable to those familiar with our PosiTector series of instruments.

Main Navigation Bar
The Main Navigation section is dynamic and may change from one screen to another.

In the above example, Search and Menu navigation options are available.

Search returns back to the list of available devices. Menu accesses the Main Menu

Connection Status Bar
Displays information about the connected instrument.

Measurement Area
Displays measurement related information. The above example shows Batch 2 (B2) is opened.

Units
Displays measurement units for the opened batch.

Carousel
The carousel is displayed when more than a single view (screen) is present. The number of dots represent the number of available views. Swipe your finger horizontally across the screen to switch between views.

Tool Bar
Displays available actions. Add a batch or reading photo's and notes. Share the batch report or data.

Menu Operation

PosiTector App functions are menu controlled. Access them by selecting Menu in the upper right of the PosiTector App display.

The Main Menu contains the following sub-menu's...

Memory

Setup

Select Exit to close the menu.

Memory Menu

The PosiTector App uses your smart device's storage for storing copied measurement data. Measurements can be reviewed on-screen, printed (AirPrint), shared via email (PDF, CSV) or synchronized with cloud-based PosiSoft.net.

The following options appear within the Memory menu.

Open (open a previously copied batch)

Close (close the currently opened batch)

Delete (delete a batch or batches from the PosiTector App)

Batch Report Configuration

Batch Report (generate a report for single batch or batches)

Sync Now

Copy from PosiSoft.net

Copy to PosiSoft.net

Open
Lists all available batches. Select the desired batch to open.

The following screen views are available when a batch is open. Swipe your finger horizontally across the screen to switch between Batch Summary and Reading views.

 

Batch Summary View
In the PosiTest AT-A example below, the batch name is B5 and it contains 2 test results (readings). The user interface is outlined as follows.

Main Navigation Bar
The Main Navigation section is dynamic and may change from one screen to another.

In the above example, Search and Menu navigation options are available.

Search returns back to the list of available devices. Menu accesses the Main Menu

Connection Status Bar
Displays information about the connected instrument.

Measurement Area
Displays measurement related information. The above example shows Batch 2 (B2) is opened.

Units
Displays measurement units for the opened batch.

Carousel
The carousel is displayed when more than a single view (screen) is present. The number of dots represent the number of available views. Swipe your finger horizontally across the screen to switch between views.

Tool Bar
Displays available actions. Add a batch or reading photo's and notes. Share the batch report or data.

Add Photo

When selected, a menu appears with the following two options.

Batch Picture
Add a photo for the current batch (group) of readings.

Batch photos and Annotations can be included in reports (default) and synchronized with PosiSoft.net. The photo can be resized or hidden from reports within the Batch Report Configuration menu.

Reading Picture
Add a photo for the currently displayed reading. See Add Reading Photo

Add Photo Annotation

This drawing tool is ideal for identifying a specific location or area within an image. Choose from three paint brush colors - Red, Green or Blue. Use finger or stylus to draw over the displayed image.

Add Notes

When selected, a menu appears with the following two options.

Batch Name/Note
Change the batch name and add batch notes using your smart device's keyboard or dictation tools.

Reading Note
Add a note for the currently displayed reading. See Add Reading Note


Batch names/notes appear on reports and are included when measurement data is synchronized with PosiSoft.net.

Batch Reading View
The Batch Summary view displays a list of all readings in the currently opened batch. Batch 5 contains two readings in the following example.

Select a reading to view complete test results including pull-off pressure, pull parameters, note, image, and the nature of the fracture (cohesive, adhesion, glue).

Add Reading Note
Click within the Note text box. A keyboard will display allowing you to enter the reading note. Click done to save the note and close the keyboard.

Add the Nature of Fracture
Upon completion of a pull-off test, the dolly and coated surface should be examined. In addition to pull-off force, many National and International standards such as ASTM D4541 and ISO 4624 require the nature of the fracture to be recorded.

The cohesive and adhesive fracture information can be recorded for up to 5 layers.


The PosiTector App displays the number of layers as set in the PosiTest AT-A. Additional layers cannot be added using the PosiTector App.

Fracture analysis is beyond the scope of this help guide. For more information see Visual Analysis and Recording of Test Results.

Reading Tool Bar

Adding Reading Photo

Add a photo using the camera

Add a photo using the gallery.

To delete a photo, select the icon and then Delete Picture.

Reading Photos and Annotations can be included in reports (default) and synchronized with PosiSoft.net. The photo can be resized or hidden from reports within the Batch Report Configuration menu.

Add Photo Annotation

This drawing tool is ideal for identifying a specific location or area within an image. Choose from three paint brush colors - Red, Green or Blue. Use finger or stylus to draw over the displayed image.

Ignore/Delete Reading, Delete Note or Photo

Ignore/Delete Reading
Select the icon and then either Ignore Reading or Delete Reading.

Ignore Readings are retained within the batch but are excluded from the report's statistical summaries and charts. Ignored readings are highlighted within the Batch Readings view. Ignored readings can be un-ignored by selecting the icon and then Un-Ignore Reading.

By default Ignored Readings are not included on reports. For inclusion, toggle the Hide Ignored Readings within the Batch Report Configuration. Ignored Readings will display has highlighted within the readings section of the report, but are excluded from the statistical summary and chart.

Delete Reading permanently removes the selected measurement from the current batch.

Delete Note
To delete a note, select the icon and then Delete Note.


Readings that have been synchronized with PosiSoft.net cannot be deleted. To exclude them from report summaries and charts select Ignore Reading.

Sharing a Batch

Share/view professional PDF reports and CSV data instantly via email, AirPrint, Dropbox or other applications on your smart device.

Report

Generate PDF reports instantly and share via email, AirPrint, Dropbox or other applications on your smart device.


Batch reports can be customized within the Batch Report Configuration menu.

Export
Email CSV (comma-delimited) comma-separated text files which can easily be imported into supporting applications such as spreadsheets and databases. A .json formatted file is also included.

 

Close Batch
Closes the current batch.

Batch measurement data is retained when a batch is closed.

Delete Batch
Permanently remove a batch of readings from the PosiTector App. Does not delete the batch from the PosiTest AT-A instrument.

Select batches for deletion, then select OK. Or select Delete all batches for all probes to permanently delete all measurement data from the smart device (phone/tablet).

If the batches have been synchronized or copied to PosiSoft.net, a copy will remain there.

Batch Report Configuration
Customize reports using the Batch Report Configuration to include/exclude nature of fracture, notes, images, logo, company/report name, fonts, alignment, image sizes and more.

Your changes are saved automatically and will be reflected the next time you generate a report.

Batch Report
Generate a report summarizing an individual batch or multiple batches. Select desired batch or batches to include in the report and press OK.

Share the report instantly via email, AirPrint, Dropbox or other applications on your device.

See Synchronization section for details on...

Sync Now
Copy to PosiSoft.net
Copy from PosiSoft.net

 

Setup menu

Info
Provides information about the currently connected instrument and PosiTector App version.

SmartLink Lock
Locks the PosiTest AT-A to the connected smart device. This prevents other PosiTector App users within range (10 m / 30 ft) from inadvertently connecting to PosiTest AT-A. This SmarLink Lock option is only visible when connected to the PosiTest AT-A.

Toggle the SmartLink Lock  within the Setup menu to lock the PosiTector SmartLink to a smart device. You will have to unlock it if you want to wirelessly connect to another smart device. Un-toggle to use the PosiTest AT-A with another smart device (default).


The PosiTest AT-A is not visible on other smart devices while you are connected (once you have selected the PosiTest AT-A from the Search screen).

Auto Sync
When toggled on; measurement data, images, nature of fracture and notes will automatically synchronize with PosiSoft.net. Synchronization occurs every time batch data changes (new reading, note, photo, etc.).

Reset
Restores factory default settings.

Suggestion: It is recommended that you synchronize all stored measurement data to PosiSoft.net prior to performing a Reset. This provides a backup solution in case measurement data has been deleted in error. Data on PosiSoft.net is not affected by a Reset.

Select Reset from the Setup Menu. The following occurs after a warning message:

-All stored batches, measurement data, images, nature of fracture, notes, annotations are deleted.

App Settings are returned to the following:

Auto Sync = OFF
Report Configuration Settings = restored to default

PosiSoft.net

PosiSoft.net is a free web-based application offering secure centralized management of measurement data. It is accessed using a standard internet browser from any location in the world.

  • View and manipulate synchronized measurement data
  • Generate reports with graphs, annotations, and images
  • Share measurement data with authorized users via a secure login from any computer or web-enabled device
  • Export data to popular formats such as XML and CSV (comma-separated values)
  • Securely store (backup) all measurement data in the Cloud


An account is not required to synchronize measurement data to PosiSoft.net.

Synchronize (Sync) with PosiSoft.net

Synchronizing copies all batch data from the PosiTector App to PosiSoft.net (no registration required). WiFi/cellular internet data connection required.

Stored batch data including measurements, photos, notes and annotations are included in the synchronization. After synchronization, data on the PosiTector App and PosiSoft.net will match (be the same).

With the exception of Batch names, information added on PosiSoft.net (notes, images) will not synchronize back to the PosiTector App. However, any changes or additions to the batch data on the PosiTector App will transfer to PosiSoft.net during the next synchronization.

Tip: Prior to synchronizing, it is good practice to change batch names to something more meaningful. This helps identify the batch in the future. Example: Rename "B4" to "Job142-14" or "Section83".

Synchronization can be triggered either manually (Sync Now) or automatically when batch data changes (Auto Sync).

Sync Now (Memory Menu)
Immediately initiates synchronization. All batches, readings, photos, notes and batch names contained within the PosiTector App will be synchronized.

A green sync icon indicates successful communication with PosiSoft.net. A red sync icon will appear if communication is not successful. If successful communication is not established after a period of time, the app will stop trying and the red icon will disappear. Ensure that your smart device has an internet/cellular data connection.

Auto Sync is an ideal backup solution for your measurement data. Data can be copied back to the PosiTector App on the same smart device or another (ideal for switching between smart devices).

To view/interact with synchronized data on PosiSoft.net, registration of your PosiTector SmartLink is required (free account).

To transfer all stored batches, select Sync Now.

Copy To/From PosiSoft.net (Memory Menu)

Sync Now  synchronizes all batch data for all instruments associated with the PosiTector App. Sometimes only a single batch or select batches is desired for transfer. Copy to or Copy from PosiSoft.net allows the selection of single or multiple batches for transfer. Ideal solution for switching between smart devices (phone and tablet). Pickup exactly where you left off.

Copy to PosiSoft.net
Select an individual batch or batches to copy to PosiSoft.net. Ideal when you don't require transferring or synchronizing all stored batches.

The selected batches will be copied to PosiSoft.net and you will be returned back to the main measurement screen.

If the batches already exist on PosiSoft.net you will be prompted with an overwrite warning message.

"At least one of the batches you selected already exists on PosiSoft.net. Press OK to overwrite existing batches. Pressing Cancel will not copy the batches"

If OK is pressed, the existing batch on PosiSoft.net will be overwritten. This action cannot be un-done.

The copied batches will be identified with a symbol within the Copy to PosiSoft.net view.

The means that the batch has been previously copied. It is not an indication that batch data is in sync. If additional measurements have been taken or batch data has changed, select Sync Now to ensure that data is in sync between the smart device and PosiSoft.net.

 

Copy from PosiSoft.net
Select an individual batch or batches to copy from PosiSoft.net to your local PosiTector App.

The means that the batch has been previously copied. It is not an indication that batch data is in sync. If additional measurements have been taken or batch data has changed, select Sync Now to ensure that data is in sync between the smart device and PosiSoft.net.


You must have connected the PosiTector App to the instrument previously to be able Copy To or From PosiSoft.net. This initial connection associates the PosiTector App with the unique identifiers (serial number and key) stored within the PosiTector SmartLink. For security purposes, this information is required for the PosiTector App to communicate with PosiSoft.net. The PosiTector App will retain this association for all connected PosiTector SmartLinks until a Reset has been performed.

Once associated, you can Copy To and From PosiSoft.net with or without the associated instrument connected.

Using the PosiTest AT-A with multiple Smart Devices

The PosiTest AT-A can be used with multiple smart devices, but only one device connection is possible at any given time. Ensure the PosiTector SmartLink is disconnected from the original smart device (close the PosiTector App or return to the Search screen). Connect the new smart device to the PosiTest AT-A.

Any new readings willl automatically be transferred to the PosiTector App (when connected). PosiTest AT-A batches that were previously copied to another smart device will not be present when connecting to a different smart device. If required, these batches can be manually copied or sent to the PosiTector App.

Batch data can be transfered between devices using the Copy to and Copy from PosiSoft.net features. Alternatively, any measurements remaining in the PosiTest AT-A's memory can be copied to the PosiTector App. Select Send Batch from the PosiTest AT-A's Connect > Bluetooth Smart menu. Select the desired batches and then Send Batch. The PosiTector App must be connected to the PosiTest AT-A for transfer.

The chosen batches will be copied from PosiSoft.net to your smart device. Open a batch by selecting Open Batch from the Memory menu.


SmartLink Lock must be off for other devices to be able to connect to the PosiTector SmartLink. Ensure this is off prior to switching smart devices.

 

Troubleshooting

PosiTest AT-A not displaying on search screen.
Ensure PosiTest AT-A is powered-up and is within range.
Refresh the search using the arrow icon in the upper left of the display.
Verify Bluetooth Smart is ON in the instruments Connect settings.

Synchronization with PosiSoft.net not successful
Ensure WiFi or cellular internet connection is available and retry.

Camera does not function when attempting to add photo
Verify adequate privacy permissions are set for the PosiTector App.

Limited Warranty, Sole Remedy and Limited Liability

DeFelsko's sole warranty, remedy, and liability are the express limited warranty, remedy, and limited liability that are set forth on its website: www.defelsko.com/terms

 

 



This manual is copyrighted with all rights reserved and may not be reproduced or transmitted, in whole or part, by any means, without written permission from DeFelsko Corporation.

DeFelsko, PosiTest and PosiTector are trademarks of DeFelsko Corporation registered in the U.S. and in other countries. iTunes and AirPrint are trademarks of Apple Inc., registered in U.S. and other countries. Other brand or product names are trademarks or registered trademarks of their respective holders.

Every effort has been made to ensure that the information in this manual is accurate. DeFelsko is not responsible for printing or clerical errors.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.